Hydropro P12 Swimming Pool Heat Pump
  • Hydropro P12 Swimming Pool Heat Pumps
  • Complete with 6m Plug and Play Cable Kit
  • In Stock For Same Day Despatch
  • Sale Prices - Cheapest Online Or We Match Price
  • Suitable For All Year Use If Sized Correctly - Call For Advice
  • 2 Year Parts & Labour Warranty

DELIVERY: Hydropro P12 Swimming Pool Heat Pumps are sent out via a specialist haulier. Delivery takes between 1-3 days.

 

RETURNS: This product can be returned in original packaging, suitable for resale, within 14 days from date of delivery. When we receive the item, our returns department confirm that everything is present and in its in original condition to ensure its eligibility for refund. We process refunds as quickly as possible. We process most refunds on the same day which they were received, but please allow up to a maximum of 14 days for the money to reach your account. It rarely takes this long, but can happen sometimes for reasons such as bank delays or errors.

PRODUCT INFO:

 

Hydropro P12/32 swimming pool heat pumps

are suitable for swimming pools up to 50m3 during the main summer months, slightly less if starting in April or the beginning of May. As the Hydropro P12 Heat Pump is one of the newest ranges of Swimming Pool Heat Pumps available they are supplied with R32 Gas

Comes complete with Plug and Play Cable Kit that needs to be installed by a competent person so perfect for inground and above ground pools

As the Hydropro P14 Heat Pump will function even when the ambient air temperature is as low as 0° Celcius they can be used all year round, but with reduced C.O.P. and output. To function correctly the heat pump will need to be sized correctly. As a very rough guide, it is suggested to at least double the Ideal Size, but it is advisable if you call us on 01322 554 870 to ensure suitability.

Hydropro P12 Heat Pump - Summer Use 

Ideal Size Pool 24ft x 12ft x 4ft Deep

Maximum Pool Size 24 ft x 12ft x 5ft Deep

To see other sizes of hydropro heat pumps click here. Full Range Of Heat Pumps

For help and advice call 01322 554 870

 

Hydropro P12/32 Heat Pump Data

 

heating power input

1.95 kW

heating capacity (A27/W27)

11.5 kW

heating capacity (A15/W26)

6.5 kW

maximum volume of pool

with good insulation

50m3 /

50,000 litres

coefficient (C.O.P.)  at A27/W27

5.90

coefficient (C.O.P.)  at A15/W25

4.59

compressor

rotary

refrigerant

R32

fan quantity

1

fan power input

90

fan rotate speed

850 RPM

fan direction

Horizontal

noise level (10 metres)

43 dB (A)

water connection

50mm

nominal water flow

4.5 m/h3

dimensions (L/W/H)

100cm / 39cm / 60cm

Type C or D Breaker Size 15 amp

Hydropro P14 Swimming Pool Heat Pump

by Bosta
Sold out
£1,475.00
  • Hydropro P14 Swimming Pool Heat Pumps
  • In Stock For Same Day Despatch
  • Sale Prices - Cheapest Online Or We Match Price
  • Suitable For All Year Use If Sized Correctly - Call For Advice
  • 2 Year Parts & Labour Warranty

DELIVERY: Hydropro P14 Swimming Pool Heat Pumps are sent out via a specialist haulier. Delivery takes between 1-3 days.

RETURNS: This product can be returned in original packaging, suitable for resale, within 14 days from date of delivery. Returns should be sent via a "Signed For" carrier or post.

When we receive the item, our returns department confirm that everything is present and in its in original condition to ensure its eligibility for refund. We process refunds as quickly as possible. We process most refunds on the same day which they were received, but please allow up to a maximum of 14 days for the money to reach your account. It rarely takes this long, but can happen sometimes for reasons such as bank delays or errors.

PRODUCT INFO:

Hydropro P14 Heat Pump is the latest Swimming Pool Heat Pump available with R32 Gas. The hydropro heat pumps are ideal for swimming pools up to 50m3 during the main summer months, slightly less if starting in April or the beginning of May.

As the Hydropro P14 Heat Pump will function down to -5° Celcius they can be used all year round. To function correctly it will need to be sized correctly. As a rough guide double the Ideal Size, but it is best if you call us on 01322 554 870

Hydropro P14 Heat Pump

Ideal Size Pool 28ft x 14ft x 4ft Deep

Maximum Pool Size 28 ft x 14ft x 5ft Deep

To see other sizes of hydropro heat pumps click here. Full Range Of Heat Pumps

For help and advice call 01322 554 870

 

Hydropro P14/32 Heat Pump Data

 

heating power input

2.35 kW

heating capacity (A27/W27)

13.5 kW

heating capacity (A15/W26)

9.8 kW

maximum volume of pool

with good insulation

60m3 /

60,000 litres

coefficient (C.O.P.)  at A27/W27

5.74

coefficient (C.O.P.)  at A15/W25

4.52

compressor

rotary

refrigerant

R32

fan quantity

1

fan power input

120

fan rotate speed

850 RPM

fan direction

Horizontal

noise level (10 metres)

43 dB (A)

water connection

50mm

nominal water flow

5.3 m/h3

dimensions (L/W/H)

116cm / 47cm / 87cm

Type C or D Breaker Size 20 amp